Make | Model | Problem | Solution | Date |
| | | |
Found: 56
|
Panasonic | Anubis B | Stuck in demo mode | Sw on mains whilst depressing "Vol" & "Prog+" on set | 14-09-04 |
Philips | 52ZY3535 Anubis B AA | No pic, sound ok with faint burning smell | No Filed - replace overheated R3452 4R7, R3450 3R9 & IC7400 TDA3653B | 14-09-04 |
|
Philips | Anubis B | ER4 displayed on screen - no text only lines. | 27Mhz Crystal 1701. | 14-09-04 |
Philips | Anubis B | HORIZONTAL GREY LINE ON SCREEN | C2413 10nF IN FIELD CCT | 14-09-04 |
Philips | Anubis B | IF IC7685 REPLACED SET WILL DISPLAY NORWEGIAN AND | MENU SET "BARNLAS" TO "FRAN" ( OFF ) THEN SET MAY BE RESET | 14-09-04 |
Philips | Anubis B | No E-W corr | R3404 47R in module 110 panel o/c | 14-09-04 |
Philips | Anubis B | no txt | 27Mhx xtal | 14-09-04 |
Philips | Anubis B | WORKS BUT LED FLASHES AND E4 ON SCREEN + NO TEXT | 27mhz XTAL ON TEXT PCB | 14-09-04 |
Philips | Anubis B AA | Dead - chopper tr s/c | Replaced opto IC7514 CNR50, Control chip IC7500 & chopper tr | 14-09-04 |
Philips | Anubis B-AA | Hor grey line over pic | Field scan has osc on it - C4213 10nF o/c | 14-09-04 |
Philips | Anubis B-AA | LED flashing with "ER4" displayed | Fault in Txt - lines only in Txt - Xtal 1701 27Mhz faulty | 14-09-04 |
Philips | Anubis B-AA | Removing "Demo" mode | Switch on whilst holding in "VOL-" & "Prog+" in together. | 14-09-04 |
Philips | Anubis B-AA | When replacing EEPROM IC7685 ST24C02P | Default language is Norwegian! & childlock (Barnlas)active. To clear childlock select spec functs option C on main menu. Next menu - Barnlas as option A - set to Fran (off). Then able to set up other parameters | 14-09-04 |
Philips | Anubis BAA | Dead with pulsing squeak | C2540 2200µ 16v leaky | 14-09-04 |
Philips | ANUBIS-B | After a while the alarm led is flashing (error 8). | Replace memory IC7685, ST24C02A (4822 209 62098)
| 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV6018
------------------------------------------------------
4822 209 33153
Hotel mode for uC P83C054-CV6018: YES
Hotel TV, so always hotel mode | 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV6012
------------------------------------------------------
Replaced by uC P83C054-CV6018; 4822 209 33153
Hotel mode for uC P83C054-CV6012: YES
Hotel TV, so always hotel mode | 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6006 | ANUBIS-B with uC P83C054-CV6006
-------------------------------
Replaced by uC P83C054-CV6107; 4822 209 33634
Hotel mode for uC P83C054-CV6006: YES
Hotel mode enabling for uC P83C054-CV6006:
1. Enter the Service Default Mode
2. Enter Service Menu | 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6014 | ANUBIS-B with uC P83C054-CV6014
-------------------------------
Replaced by uC P83C054-CV6107; 4822 209 33634
Hotel mode for uC P83C054-CV6014: YES
Hotel mode enabling for uC P83C054-CV6014:
1. Enter the Service Default Mode
2. Enter Service Menu | 14-09-04 |
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6107 | ANUBIS-B with uC P83C054-CV6107
-------------------------------
4822 209 33634
Hotel mode for uC P83C054-CV6107: YES
Hotel mode enabling for uC P83C054-CV6107:
1. Enter the Service Default Mode
2. Enter Service Menu by pressing simultaneously "VOL | 14-09-04 |
Philips | ANUBIS-B | At switching-off, spot on the middle of the screen. | Change capacitor C2470 from 22uF into 4.7uF - 4822 124 80143
| 14-09-04 |
Philips | ANUBIS-B | Auto contrast function not optimal. | Change:
R3614 into 82k (4822 116 52304)
R3633 into 270k (4822 051 10274)
R3657 into 15K (4822 051 10153)
R3681 into 30K (4822 116 52267)
R3685 into 6k8 (4822 051 10682).
REMARKS :
Introduced in production in week 9242.
| 14-09-04 |
|
Philips | ANUBIS-B | Bad picture. Picture out of focus. | Leak current in CRT socket. Replace CRT socket (4822 255 70251).
| 14-09-04 |
Philips | ANUBIS-B | Colours disappears. | Check capacitor C2269 (22nF; 4822 126 11544) on the mains PCB.
| 14-09-04 |
Philips | ANUBIS-B | Correction to service manual | Correction to service manual
----------------------------
In the spare parts list of service manual ANUBIS B AA two part
numbers are quoted for the line output transformer and also for the
line linearity coil. The component used depends on the picture
tu | 14-09-04 |
Philips | ANUBIS-B | Drift of varicap voltage. | Delete C2606.
REMARKS :
Introduced in production from production code PM009223 or higher.
| 14-09-04 |
Philips | ANUBIS-B | Error codes | Error codes
-----------
The error codes for the Anubis B Hotel TV (xxHTxxxx/xx) is not
published yet:
For the total overview herewith a table is given for both the normal
Anubis B and the Anubis B Hotel:
Error LED Anubis B An | 14-09-04 |
Philips | ANUBIS-B | From stand-by, by pressing "program -/+", "E3" will be shown | Change the value of C2560 to 1000 uF (4822 124 40214). Change the
value of R3452 to 1 Ohm (4822 052 10108). Change the value of R3782
to 18 Ohm (4822 053 10189).
| 14-09-04 |
Philips | ANUBIS-B | Horizontal black stripe | Distorted saw-tooth signal at input vertical amplifier.
Check C2413 10nF (4822 122 32442).
| 14-09-04 |
Philips | ANUBIS-B | Horizontal white line at the top side. | Vertical deflection fault, bad contact R3415 (820R 4822 053 11821).
| 14-09-04 |